Kw phase
Top sales list kw phase
South Africa
Diesel Generator 11kVA Silent Diesel Canopy type. SPEC's:- SILENT TYPE (CANOPY,SOUNDPROOF TYPE) P-11S PRIME POWER (KW ⁄ KVA) 8.8 KW 11 KVA STANDBY POWER (KW ⁄ KVA) 9.68 KW 12.1 KVA VOLTAGE (V) @ 50HZ⁄1500RPM 415⁄240V GEN-SET PHASE THREE-PHASE GEN-SET CONTROL SYSTEM DIGITAL CONTROL PANEL MUFFLER SYSTEM (EXHAUST) INDUSTRY CLASS DIESEL ENGINE TYPE PERKINS 403A-15G1 Direct Injection, water-cooling NUMBER OF CYLINDERS 3 STARING MODE 12V electric starting SPEED CONTROL TYPE Mechanical RATED POWER (KW) 10.4 MAX. POWER (KW) 11.44 ENGINE DISPLACEMENT (L) 1.496 COMPRESSION RATIO 22.5:1 BORE × STROKE (MM) 84*90 LUBRICATION CAPACITY (L) 6 FUEL CONSUMPTION RATE g⁄kw.h 240 100% FUEL DIESEL CONSUMPTION (L)2.496 75%FUEL DIESEL CONSUMPTION (L)1.872 50% FUEL DIESEL CONSUMPTION (L)1.248 A,CALTERNATOR ALTERNATOR TYPE Type of Stamford EXCITATION TYPE Self-excitation with AVR INSULATION Class "H" PROTECTION CLASS IP23 RATED POWER (KW⁄KVA) 8.8KW ⁄ 11KVA VOLTAGE SINGLE-PHASE (V) 220⁄230⁄240 THREE-PHASE (V) 415 RATED SPEED (r⁄min) 1500 GEN-SET OUTSIDE DIMENSION (MM) SILENT TYPE L 1700 W 860 H 1060 NOISE db(A) @ 7M ≤68-75 Net weight (kg) 530 Warranty period - 5 years Automatic transfer switch. Full service and replacements parts available Transportation can be arranged if required with Free Installations
R 18.900
See product
South Africa
Automatic Starting System - (to work with Automatic Transfer Switch) Battery Charging Alternator Critical Muffler Included on Enclosed Units - Available as Option on Open Units Factory Loadbank Tested Skid Mounted Generator Type: - Diesel Single Phase Reconnectable Digital Control Panel Sound Attenuated Weather Proof Enclosure - Available as Option on Open Units Stamford Newage Generator End EPA Certified Stamford Alternator - 60 Hz Power Rating: Single Phase: Standby Power Rating: 17 kVA / 14 kW Prime Power Rating: 17 kVA / 14 kW
R 21.000
See product
South Africa
Stamford Alternator 60 Hz Power Rating: Three Phase: Standby Power Rating: 29 kVA / 23 kW Prime Power Rating: 25 kVA / 20 kW Automatic Starting System - (to work with Automatic Transfer Switch) Battery Charging Alternator Critical Muffler Included on Enclosed Units - Available as Option on Open Units Factory Loadbank Tested Skid Mounted Generator Type: - Diesel 3 Phase Reconnectable Digital Control Panel Sound Attenuated Weather Proof Enclosure - Available as Option on Open Units 8 Hour Base Mounted Fuel Tank Stamford Newage Generator End EPA Certified
R 28.600
See product
South Africa (All cities)
60 Hz Power Rating: Three Phase: Standby Power Rating: 29 kVA / 23 kW Prime Power Rating: 25 kVA / 20 kW Automatic Starting System - (to work with Automatic Transfer Switch) Battery Charging Alternator Critical Muffler Included on Enclosed Units - Available as Option on Open Units Factory Load bank Tested Skid Mounted Generator Type: - Diesel - 3 Phase Re-connectable Digital Control Panel Sound Attenuated Weather Proof Enclosure - Available as Option on Open Units 8 Hour Base Mounted Fuel Tank Stamford New age Generator End EPA Certified. Flat Racks Innovative and cost effective transportation available. Transport / delivery if required is provided at very competitive rates. To place order, kindly visit our website. Interested Buyers Please contact Us.Interested Buyers Please contact Us. Contact Number: +27(0)723757319 Website: www.delacpowergenset.co.za Email: sales@delacpowergenset.co.za
R 28.600
See product
South Africa
Stamford Alternator - 60 Hz Power Rating: Single Phase: Standby Power Rating: 10.7 kVA / 8.6 kW Prime Power Rating: 8.6 kVA / 7.9 kW. To place order, kindly visit our website. Interested Buyers Please contact Us. Contact Number: +27(0)723757319 Website: www.delacpowergenset.co.za Email: info@delacpowergenset.co.za
R 16.800
See product
South Africa (All cities)
This system operates using diesel to power a high reliability Yanmar diesel engine that drives a synchronous electrical generator. This electrical generator is a compact brushless design featuring automatic output voltage regulation to compensate for load and temperature variations. Stamford Alternator - 60 Hz Power Rating: Single Phase: Standby Power Rating: 10.7 kVA / 8.6 kW Prime Power Rating: 8.6 kVA / 7.9 kW Flat Racks Innovative and cost effective transportation available. Transport / delivery if required is provided at very competitive rates. To place order, kindly visit our website. Interested Buyers Please contact Us.
R 16.800
See product
South Africa (All cities)
Hyundai 14kVA 3-Phase DHY11KSEm Silent Diesel ATS Generator. IN STOCK A powerful Three phase generator which produces up to 14kVA. Powered by a 1500rpm diesel engine, ideal for ensuring the lifespan of the machine. Fitted with an AVR alternator to produce a clean energy output. Housed in a “silenced” weather-proof canopy. Can be paired with an ATS system for an automatic transfer of power. TECHNICAL SPECIFICATIONS. ========================== Dimensions (mm): Length 1900 x Width 900 x Height 1070 Rated Power (kW/kVA): 10kVA / 10kW Max Power (kW/kVA): 11kVA / 11kW Voltage(s): 230 Controller: IL-NT MRS 10 ATS Port: Included Battery (Ah): 12v, 120ah Fuel Capacity (L): 77.5 Cooling Fluid Volume (L): 10 Rotate Speed: 1500rpm Speed Regulation: Mechanical Alternator: AVR Power Factor (Cosφ): 1.0 Voltage Regulation: AVR/BRISHLESS Low Oil Pressure: Yes Block On Startup: Yes Low Battery: Yes High Temperature On Water: Yes Low Oil Level: Yes Low Running On Engine: Yes Emergency Stop: Yes N.G. (kg.): 640 Noise @ 1m: 92 Noise @ 7m: 65 Weight: 710kg Genesis Gen is the leading Dealer of Perkins, Yanmar, Cummins and Hyundai powered diesel generators in South Africa. And we also offering easy installations. CONTACT DETAILS. Website: www.ggpsltd.co.za Email: sales@ggpsltd.co.za Tel: +27(81)243-2296 Fax: +27(0)864356709
R 22.499
See product
2 photos
South Africa (All cities)
Hyundai 14kVA 3-Phase DHY11KSEm Silent Diesel ATS Generator. IN STOCK A powerful Three phase generator which produces up to 14kVA. Powered by a 1500rpm diesel engine, ideal for ensuring the lifespan of the machine. Fitted with an AVR alternator to produce a clean energy output. Housed in a “silenced” weather-proof canopy. Can be paired with an ATS system for an automatic transfer of power. TECHNICAL SPECIFICATIONS. ========================== Dimensions (mm): Length 1900 x Width 900 x Height 1070 Rated Power (kW/kVA): 10kVA / 10kW Max Power (kW/kVA): 11kVA / 11kW Voltage(s): 230 Controller: IL-NT MRS 10 ATS Port: Included Battery (Ah): 12v, 120ah Fuel Capacity (L): 77.5 Cooling Fluid Volume (L): 10 Rotate Speed: 1500rpm Speed Regulation: Mechanical Alternator: AVR Power Factor (Cosφ): 1.0 Voltage Regulation: AVR/BRISHLESS Low Oil Pressure: Yes Block On Startup: Yes Low Battery: Yes High Temperature On Water: Yes Low Oil Level: Yes Low Running On Engine: Yes Emergency Stop: Yes N.G. (kg.): 640 Noise @ 1m: 92 Noise @ 7m: 65 Weight: 710kg We are the Supplier and Dealer of Perkins, Yanmar, Cummins and Hyundai powered diesel generators in South Africa. And we also offering easy installations. CONTACT DETAILS. Website: www.ggpsltd.co.za Email: sales@ggpsltd.co.za Tel: +27(78) 732-8925 Fax: +27(0)864356709
R 22.499
See product
South Africa
Alternator Model SC-184E Rated Frequency (Hz) 50 Rated Voltage (V) 230 / 400 Rated Current (A) Per Phase 29 Rated Output/Prime Power (kVA) 20 Max Output/Standby Power (kVA) 21 Rated Rotation Speed 1500 Power Factor cosØ 0.8 Pole Number 4 Phase Number Single Phase Diesel Engine Specifications Engine Brand FAW Model Type XC-4DW91-29D Type Four cylinder: vertical, four stroke, water cooled, in-line, direct injection diesel engine Starting System 12 Volt Electric Starter Auto-Decompression for easy starting Yes Displacement (L) 2.543 Compression Ratio 18:1 Rated Power (kW / rpm) 24 / 1500 Fuel Type Diesel Lube Oil L-ECD grade or 15W40 Low Pressure alert System Yes Low fuel cut out protection Yes General Specifications Fuel Tank Capacity (L) 50 Continuous Running time @ full load (Hr) 8 @ full load Dimensions: (L x W x H) 1750*750*850 (mm) Weight (Kg) 540 Structure Type Silent Enclosure Noise Level (dBA @ 7m) 64 - 68 AVR Constant voltage AVR Excitation Mode Self Excitation Panel Type Digital Control Panel Control Panel GU3311 ISO9001 & CE certified Yes
R 22.500
See product
South Africa (All cities)
Powerful Hyundai DHY9KSEm Standby Generator Dimensions (mm): Length 1500 x Width 760 x Height 1070 Rated Power (kW/kVA): 8.0kw/8.0kva Max Power (kW/kVA): 8.8kw/8.8kva Frequency: 50 Voltage(s): 115, 230 Controller: IL-NT MRS 10 ATS Port: Included Battery (Ah): 1X12V – 36Ah Fuel Capacity (L): 42 Cooling Fluid Volume (L): 10 Fuel Consumption (l/h): 1.8 / 3.5 Engine Model: HY380 Power Output (hp): 11 Rotate Speed: 1500rpm Speed Regulation: Mechanical Displacement: 1357 Oil Capacity (L): 10 Alternator: AVR Power Factor (Cosφ): 1.0 Voltage Regulation: AVR / BRUSHLESS Low Oil Pressure: Yes Block On Startup: Yes Low Battery: Yes High Temperature On Water: No Low Oil Level: Yes Low Running On Engine: Yes Emergency Stop: Yes N.G. (kg.): 460 Noise @ 1m: 92 Noise @ 7m: 65 Weight: 530kg.
R 20.499
See product
Nelspruit (Mpumalanga)
KW: 0.6 400V / Three Phase Non Self Priming Liquid type: Clean Water Uses: domestic Applications: water supply systems, pressure systems, irrigation pumps typology: surface Family: peripheral
R 6.926,45
See product
Nelspruit (Mpumalanga)
KW: 0.37 400V / Three Phase Non Self Priming Liquid type: Clean Water Uses: domestic Applications: water supply systems, pressure systems, irrigation pumps typology: surface Family: peripheral
R 3.614,44
See product
South Africa
KOHLER 10KVA GAS GENERATOR (LPG). Rated kW LP 10kVA Rated kW NG 6.0 kW Amps LP 111 amps Amps NG 111 amps Peak Motor Starting kVA @240 V 10 kVa Alternator Note All information shown is for 1 Phase 60 Hz generator with the largest alternator option available. Displacement 725 cm3 (44 cu. in.) Horsepower NG 18.5 HP, LP 21.2 HP Enclosure Material Steel Sound Output During Full-speed 72 dB(A) Response Time 10 seconds Warranty Premium five-year limited warranty Country of Origin US Certifications/Listings EPA|CSA|UL 2200|cUL Automatic Transfer Switch YES Remote Monitoring Available Included Off Grid / Utility Backup Utility Backup Weight 375 lbs. Alternator Type 2-Pole, Rotating Field Fuel Consumption on NG at50% 64 cfh Fuel Consumption on LP at 50% 51 cfh Controller RDC2 Digital Controller Cylinder Arrangement Single Cylinder Dimensions 712mm x 777mm x 824mm (28 in. x 30 in. x 32.4 in.) Engine Manufacturer/Description KOHLER Engine Model SV620 Engine/Alternator RPM3600 Fuel TypeLPG|Natural Gas Frequency Variable Speed, Direct Current Phase Single Phase Voltage @ 60 Hz 120/240 Digital Voltage Regulation ±1.0% Built in Mounting Pad Yes
R 19.900
See product
South Africa
KOHLER 20kW Stationary Back-Up Power Generator LP Vapor Natural Gas ATS 20RESAL. Rated kW LP 33.3kVA Rated kW NG 18 kW Amps LP 83.3 amps Amps NG 75.0 amps Peak Motor Starting kVA @240 V 40.5 kVa Alternator Note All information shown is for 1 Phase 60 Hz generator with the largest alternator option available. Displacement 999 cm3 (61 cu. in.) Horsepower NG 27.1 HP, LP 30.9 HP Enclosure Material Composite Sound Output Weekly 64 dB(A) Sound Output Full-speed 69 dB(A) Response Time 10 seconds Warranty Premium five-year limited warranty Country of Origin US Certifications/Listings EPA|UL 2200 Automatic Transfer Switch Yes Remote Monitoring Available Yes Off Grid / Utility Backup Utility Backup Weight 580 lbs. Alternator Type 2-Pole, Rotating Field Fuel Consumption on NG at50% 161 cfh Fuel Consumption on LP at 50% 82 cfh Controller DC2 Digital Controller Cylinder Arrangement V-2 Dimensions 1216mm x 655mm x 733mm (48 in. x 26.2 in. x 29 in.) Engine Manufacturer/Description KOHLER Engine Model CH1000 Engine/Alternator RPM3600 Fuel TypeNatural Gas|LPG Frequency 60 Hz|50 Hz Phase Single Phase Voltage @ 60 Hz 120/240 Digital Voltage Regulation ±1.0% Built in Mounting Pad Yes
R 45.000
See product
South Africa
Rated kW LP 20 kVA Rated kW NG 11 kW Amps LP 50.0 amps Amps NG 45.8 amps Peak Motor Starting kVA @240 V 20.3 kVa Alternator Note All information shown is for 1 Phase 60 Hz generator with the largest alternator option available. Displacement 725 cm3 (44 cu. in.) Horsepower NG 18 HP, LP 21.4 HP Enclosure Material Composite Sound Output Weekly 67 dB(A) Sound Output Full-speed 71 dB(A) Response Time 10 seconds Warranty Premium five-year limited warranty Country of Origin US Certifications/Listings EPA|UL 2200 Automatic Transfer Switch Yes Remote Monitoring Available Yes Off Grid / Utility Backup Utility Backup Weight 489 lbs. Alternator Type 2-Pole, Rotating Field Fuel Consumption on NG at50% 128 cfh Fuel Consumption on LP at 50% 57 cfh Controller DC2 Digital Controller Cylinder Arrangement V-2 Dimensions 777mm x 712mm x 824mm (30.6 in. x 28 in. x 32.4 in.) Engine Manufacturer/Description KOHLER Engine Model CH1000 Engine/Alternator RPM3600 Fuel TypeNatural Gas|LPG Frequency 60 Hz|50 Hz Phase Single Phase Voltage @ 60 Hz 120/240 Digital Voltage Regulation ±1.0% Built in Mounting Pad Yes
R 28.500
See product
Jan Kempdorp (Northern Cape)
Alternator Specifications Alternator Model SC-184D Rated Frequency (Hz) 50 Rated Voltage (V) 230 / 400 Rated Current (A) Per Phase 45 Rated Output/Prime Power (kVA) 29 Max Output/Standby Power (kVA) 32 Rated Rotation Speed 1500 Power Factor cosØ 0.8 Pole Number 4 Phase Number Three Phase "Y" type connection Diesel Engine Specifications Engine Brand FAW Model Type XC-4DX21-45D Type Four cylinder: vertical, four stroke, water cooled, direct injection diesel engine Starting System 12 Volt Electric Starter Auto-Decompression for easy starting Yes Displacement (L) 3.857 Compression Ratio 18:1 Rated Power (kW / rpm) 33 / 1500 Fuel Type Diesel Lube Oil L-ECD grade or 15W40 Low Pressure alert System Yes Low fuel cut out protection Yes General Specifications Fuel Tank Capacity (L) 75 Continuous Running time @ full load (Hr) 8 @ full load Dimensions: (L x W x H) 2000*850*850 (mm) NETT Weight (Kg) 730 Structure Type Silent Enclosure Noise Level (dBA @ 7m) 64 - 68 AVR Constant voltage AVR Excitation Mode Brushless / Self Excitation Panel Type Digital Control Panel Control Panel GU3311 ISO9001 & CE certified Yes
R 31.000
See product
South Africa (All cities)
Selling FBG2800CX,AC230V SINGLE PHASE RATED OUTPUT 2.5 KW For R2500 first come. Stay near alberton can come collect if needed
See product
South Africa (All cities)
External Size:1623W X 803H X 1075DCapacity:2 x Roll-in Trolleys for bread pans 40 Trays Power:220 V Single Phase 3 kW, 15 Amps Convection Oven Provers have single glazed glass doors for clear viewing of the proving process. Baking Oven Provers have Stainless Steel Doors. Self-controlled water supply. Thermostatic temperature control. Steam and dry heat (Wet and Dry Element) WDA46 Best Price On Catering Equipment Website: https://www.retailroute.co.za WhatsApp Support Line: +27718309723 Gmail: retailroutestore@gmail.com Business Email: buy@retailroute.co.za
R 21.000
See product
Nelspruit (Mpumalanga)
Three-Phase KW: 2.2 400V / Three Phase Non Self Priming Liquid type: Clean Water Uses: domestic Applications: water supply systems, pressure systems, irrigation pumps typology: surface Family: peripheral
R 12.647,70
See product
Nelspruit (Mpumalanga)
Three-Phase KW: 1.1 400V / Three Phase Non Self Priming Liquid type: Clean Water Uses: domestic Applications: water supply systems, pressure systems, irrigation pumps typology: surface Family: peripheral
R 1.142,34
See product
Nelspruit (Mpumalanga)
Three-Phase KW: 0.75 400V / Three Phase Non Self Priming Liquid type: Clean Water Uses: domestic Applications: water supply systems, pressure systems, irrigation pumps typology: surface Family: peripheral
R 8.191,45
See product